Atm statistics screen, Atm statistics screen -30 – Verilink WANsuite 6x30 (34-00315.B) Product Manual User Manual
Page 58

3-30
W A N s u i t e 6 x 3 0
•
Max VPI Bits – The default Max Virtual Path Identifier Bits value is 3 for
VPI values ranging from 0 to 8.
•
Max VCI Bits – The default Max Virtual Channel Identifier Bits value is 6
for VCI values ranging from 32 to 63.
To change an ATM Service configuration, enter the desired value for each
parameter and click on the “Submit” button.
The Status table provides the following status information on the circuits:
•
OperStatus (Operation Status)
•
Opened VCCs
•
Unopened VCCs
•
Current Max VPI Bits
•
Current Max VCI Bits
The ATM Service Details screen provides the user-activated buttons described
below.
ATM Statistics Screen
Clicking on the “ATM Statistics” button on the ATM Service Details screen
will display the screen shown in Figure 3.27.
Figure 3.27
ATM Statistics Screen
Button
Function
Submit
Sets any values that have been changed.
ATM Statistics
Displays the current ATM statistics.
Virtual Channels
Displays configured VCCs.
QoS Profiles
Displays configured QoS profiles.
Refresh
Refreshes data on the current page.