Verilink WANsuite 6x30 (34-00315.B) Product Manual User Manual

Page 59

Advertising
background image

W e b S e r v e r I n t e r f a c e

3-31

There are ninety-six 15-minute “buckets” available for ATM statistics. If the
unit is powered on at 01:00 PM, the first interval will be completed at 01:15
PM; subsequent intervals would be completed at xx:30, xx:45, xx:00 and
xx:15. Interval 1 is always the latest (most recent) interval, and interval 96
will always be the oldest.

The table on the ATM Statistics screen shows a summary that includes all 96
buckets. You can choose to see the statistics for any given bucket by selecting
the desired Period Index from the pull-down menu and clicking the “Submit”
button. Alternatively, you can display all intervals at once by clicking the “All
ATM Intervals” button beneath the table. The MIB (ipad.mib) describes each
available statistic.

The ATM Statistics table is divided into three sections: Transmit, Receive and
Status. Each section provides real-time updates on the following statistics:

Transmit section

Frames

current number of good frames transmitted

Errored Frames

current number of frames in error

Bytes

current number of bytes sent

Receive

Frames

current number of good frames received

Errored Frames

current number of frames in error

Bytes

current number of bytes received.

Status

Opened VCCs

number of opened VCCs

Unopened VCCs

number of unopened VCCs

Use the pull-down menu in the Period Index row of the table to select the
interval for which you want to see ATM statistics. You may choose any of the
96 intervals, the current statistics, or a summary of the past 24-hour period.
The default setting is a Summary of all intervals.

ATM Statistics (All Intervals) Screen

Clicking on the “All ATM Intervals” button on the ATM Statistics screen will
display a table (Figure 3.28) that summarizes the transmit and receive statistics
for the current time interval and all intervals recorded during the current 24-hour
reporting period.

Advertising