Performance screens, Performance screens -8 – Verilink WANsuite 6x30 (34-00315.B) Product Manual User Manual

Page 36

Advertising
background image

3-8

W A N s u i t e 6 x 3 0

Applicable values range from 000 through 900. A value of “000” means the
alarm will never be reset. Default is 30 seconds.

The Network screen provides the user-activated buttons described in the table
below.

CAUTION:

Performance data will be lost upon power cycle or after performing a
Maintenance Reset or a Save and Restart.

Performance Screens

Click on the “Performance” button at the bottom of the Network screen to
bring up a Network Performance/Summary table. In addition to the error
parameters found in the Error Status and Alarm Thresholds Table on
page 3-6,
the error parameters described below are included on the Network
Performance/Summary table. From this screen, you can access the Network
Performance 24 Hour screen (Figure 3.6) or the Network Performance 30 Day
screen (Figure 3.7).

Button

Function

Submit

Sets any values that have been changed.

Clear Alarms

Resets the alarm conditions and counts to zero.

Performance

Displays a Performance/Summary screen (Figure 3.5) that
shows a current count of the number of error events that have
occurred over the past 24 hours and the past 30 days.

Channels

Displays the Channel Table Details screen, showing each
channel by index number. Each channel’s rate and service (by
number) are displayed and can be changed through user input.

Network Services

Displays the Services screen for the Network interface.

Refresh

Refreshes data on the current page.

Advertising