Restoring all factory default settings – ProSoft Technology ILX34-AENWG User Manual

Page 101

Advertising
background image

ILX34-AENWG ♦ Point I/O Platform

Diagnostics and Troubleshooting

Wireless POINT I/O Adapter

User Manual

ProSoft Technology, Inc.

Page 101 of 177

August 16, 2013

4 Wait for at least one minute. During this one minute, the firmware will write

default settings to the EEPROM that will take effect the next time module
power is turned on.

To ensure a one minute delay, open a command prompt window, enter:

ping localhost –n 60 && exit

then wait until the command prompt window closes.

5 Observe the Point Bus Status LED. Initially it will be RED, then it will become

GREEN, then it will turn off. Verify that it is not lit before disconnecting power.

WARNING: Do NOT remove power while the Point Bus Status LED is GREEN.

6 Change the thumbwheels to any value other than 888 or 777.
7 Turn module power on.

Firmware Version 3.5.0 and later
1
Turn module power off.
2 Change thumbwheels to 888.
3 Turn module power on.
4 The Point Bus Status LED will come on solid RED.

WARNING: Do NOT power off the ILX34 while the Point Bus Status LED is on.

5 After about 30 seconds, the Point Bus Status LED will go out. Once it does,

you can power off the module safely.

6 Change the thumbwheels to any value other than 888 or 777.
7 Turn module power on.

NOTE: The Ethernet link is disabled when the thumbwheels are set to 888.

After a successful restart at the end of either procedure, if thumbwheels are set
to a value from 001 to 254, then the number on the thumbwheels will become the
last octet of the IP address, 192.168.1.XXX, where XXX is the value set on the
thumbwheels. If the value on the thumbwheels are set to any number over 254
(except 888 and 777), then BOOTP is enabled and you can use a BOOTP utility
to set the IP address.

After either of the above procedures, the following settings will be reset to these
factory default settings:
 The DHCP Enabled function is enabled (set to T

RUE

).

 The Auto Negotiate functions of the Ethernet network and the wireless

network are set to T

RUE

.

 The Web server is enabled.
 The password for this page resets to the factory default of "

PASSWORD

".

4.9

Restoring All Factory Default Settings

1 Turn module power off.

Advertising