Present / Latched Data
To interpret values from -2,147,483,648 to -1, use this conversion formula:
 Stored Data Tag Value + 4,294,967,296 = Actual Stored Data Tag Value.

Example: for a read value of -1,794,967,296:
-1,794,967,296 + 4,294,967,296 = 2,500,000,000 actual value

1734-SSI

1734 POINT I/O Catalog Number

RSLogix5000 Module Description

1734-SSI

1 Channel Synchronous Serial Interface

Output Data

Data Type

Default Value

Valid Data Values

Control

SINT

0

Latch Acknowledge

BIT 0

0

0=Latch Not Cleared
1=Latch Cleared

Compare 0 Acknowledge

BIT 1

0

0=Compare0 Not Reset
1=Compare0 Reset

Compare 1 Acknowledge

BIT 2

0

0=Compare1 Not Reset
1=Compare1 Reset

Compare 0 Select

BIT 3

0

0=Compare0 Not Selected
1=Compare0 Selected

Compare 1 Select

BIT 4

0

0=Compare1 Not Selected
1=Compare1 Selected

1734-232ASC

1734 POINT I/O Catalog Number

RSLogix5000 Module Description

1734-232ASC

1 Channel ASCII Interface Module

Configuration Data

Data Type

Default Value

Valid Data Values

Serial Character Format
(ASCII Format:
Data Bits / Parity / Stop)

SINT

0

0=7N2
1=7E1
2=7O1
3=8N1
4=8N2
5=8E1
6=8O1
7=7E2
8=7O2

Serial Comm Speed
(Communication Rate of the Serial Port)

SINT

0

0=9600 Kbps
1=1200 Kbps
2=2400 Kbps
3=4800 Kbps
4=19.2 KBps
5=38.4 KBps