Configure the ILX34-AENWG

ILX34-AENWG ♦ Point I/O Platform

User Manual

Wireless POINT I/O Adapter

Page 40 of 177

ProSoft Technology, Inc.

August 16, 2013

1 In the Module Definition area of the General tab, click the C

HANGE

button.

This action opens the M

ODULE

D

EFINITION

dialog box.

2 Select the Chassis Size for your project from the dropdown list, and then

Click OK

to close the M

ODULE

D

EFINITION

dialog box. In a later step, you will

verify the chassis size when you are online with the Configure 1734 POINT
I/O Modules (page 40).

2.4

Add POINT Modules Under the Adapter

1 Right-click the ILX34-AENWG

adapter under I/O configuration to add a new

module.

Your second module is in slot 1.

2 Select the module from the

M

ODULE

T

YPE

list, and click OK.

3 In the

M

ODULE

P

ROPERTIES

dialog, enter the following information:

a) Name
b) Slot

4 Click the C

ONNECTION

tab, and set the RPI:

o

For digital modules, enter 10 ms

o

For analog or specialty modules, enter 50 ms.

5 Click F

INISH

.

Repeat these steps to add all of the POINT I/O modules connected to the
ILX34-AENWG adapter.

2.5

Configure 1734 POINT I/O Modules

The preferred method to configure POINT I/O modules is to use the M

ODULE

P

ROPERTIES

dialog box for each POINT I/O module, as described in the User

Manual for the module. The following steps show you how to configure the
module by editing the Controller Tags.

1 In the C

ONTROLLER

O

RGANIZATION

window, double-click C

ONTROLLER

T

AGS

,

and then click the M

ONITOR

T

AGS

tab, at the bottom left corner of the

Controller Tags dialog box.