Set spantree lpwindow, Show spantree lpwindow – Enterasys Networks Enterasys D2 D2G124-12P User Manual

Page 238

Advertising
background image

set spantree lpwindow

6-46 Spanning Tree Configuration

set spantree lpwindow

Use this command to set the Loop Protect event window value in seconds.

Syntax

set spantree lpwindow value

Parameters

Defaults

None. 

Mode

Switch command, read‐write.

Usage

The Loop Protect Window is a timer value, in seconds, that defines a period during which Loop 
Protect events are counted. The default value is 180 seconds. If the timer is set to 0, the event 
counter is not reset until the Loop Protect event threshold is reached. If the threshold is reached, 
that constitutes a loop protection event.

Example

This example shows how to set the Loop Protect event window to 120 seconds:

D2(rw)->set spantree lpwindow 120

show spantree lpwindow

Use this command to display the current Loop Protect event window value.

Syntax

show spantree lpwindow

Parameters

None.

Defaults

None. 

Mode

Switch command, read‐only.

Example

This example shows how to display the current Loop Protect window value:

D2(rw)->show spantree lpwindow
The Loop Protect event window is set to 120 seconds

value

Specifies the number of seconds that comprise the period during which 
Loop Protect events are counted. The default event window is 180 
seconds.

Advertising