Clear logging application, Clear logging application -8, 38 mnemonic values for logging applications -8 – Enterasys Networks Enterasys D2 D2G124-12P User Manual

Page 346: Table 12‐38, Table 12-38

Advertising
background image

clear logging application

12-8 Logging and Network Management

Defaults

If level is not specified, none will be applied.

Mode

Switch command, read‐write.

Example

This example shows how to set the severity level for SNMP to 4 so that error conditions will be 
logged for that application.

D2(rw)->set logging application SNMP level 4

clear logging application

Use this command to reset the logging severity level for one or all applications to the default value 
of 6 (notifications of significant conditions).

Syntax

clear logging application {mnemonic | all}

level level

(Optional) Specifies the severity level at which the server will log 
messages for applications. Valid values and corresponding levels are:

1 — emergencies (system is unusable)

2 — alerts (immediate action required)

3 — critical conditions

4 — error conditions

5 — warning conditions

6 — notifications (significant conditions)

7 — informational messages

8 — debugging messages

Table 12-38

Mnemonic Values for Logging Applications

Mnemonic

Application

CLIWEB

Command Line Interface and Webview management

SNMP

Simple Network Management Protocol

STP

Spanning Tree Protocol

Driver

Hardware drivers

System

Non-application items such as general chassis management

Stacking

Stacking management (if applicable)

UPN

User Personalized Networking

Router

Router

Advertising