DC Braking Settings

The DC braking feature can provide
additional stopping torque when
compared to a normal deceleration to a
stop. DC braking is particularly useful
at low speeds when normal decelera-
tion torque is minimal. When you
enable DC braking, the inverter injects
a DC voltage into the motor windings
during deceleration below a frequency you can specify (A052). The braking power
(A054) and duration (A055) can both be set. You can optionally specify a wait time
before DC braking (A053), during which the motor will free run (coast).

CAUTION: Be careful to avoid specifying a braking time that is long enough to cause
motor overheating. If you use DC braking, we recommend using a motor with a built-in
thermistor, and wiring it to the inverter’s thermistor input (see

“Thermistor Thermal

Protection” on page 4–25

). Also refer to the motor manufacturer’s specifications for

duty-cycle recommendations during DC braking.

DC braking

Free run

Running

t

0

+

A053

A055

“A” Function

Run

Mode

Edit

Lo Hi

Defaults

Func.

Code

Name /

SRW Display

Description

–FE(F)

(EU)

–FU

(USA)

Units

A051 DC braking enable

Two options; select codes:
00 .. Disable
01 .. Enable

✘ ✔

00

00

DCB Mode OFF

A052 DC braking frequency

setting

The frequency at which DC
braking begins,
range is from the start
frequency (B082) to 60 Hz

✘ ✔

0.5

0.5

Hz

DCB F 0000.5Hz

A053 DC braking wait time

The delay from the end of
controlled deceleration to start
of DC braking (motor free runs
until DC braking begins),
range is 0.0 to 5.0 sec.

✘ ✔

0.0

0.0

sec.

DCB Wait 0000.0s

A054 DC braking force for

deceleration

Level of DC braking force,
settable from 0 to 100%

✘ ✔

0.

0.

%

DCB V 00000%

A055 DC braking time for

deceleration

Sets the duration for DC
braking, range is 0.0 to 60.0
seconds

✘ ✔

0.0

0.0

sec.

DCB T 0000.0s

A056 DC braking / edge or

level detection for [DB]
input

Two options; select codes:
00 .. Edge detection
01 .. Level detection

✘ ✔

01

01

DCB KIND LEVEL