Troubleshooting Tips

The table below lists typical symptoms and the corresponding solution(s).

Symptom/condition

Probable Cause

Solution

The motor

will not run.

The inverter

outputs [U], [V],

[W] are not

supplying

voltage.

•

Is the frequency command source
A001 parameter setting correct?

•

Is the Run command source A002
parameter setting correct?

•

Make sure the parameter
setting A001 is correct.

•

Make sure the parameter
setting A002 is correct.

•

Is power being supplied to termi-
nals [L1], [L2], and [L3/N]? If so,
the POWER lamp should be ON.

•

Check terminals [L1], [L2],
and [L3/N], then [U/T1],
[V/T2], and [W/T3].

•

Turn ON the power supply
or check fuses.

•

Is there an error code

E X X

displayed?

•

Press the Func. key and
determine the error type.
Eliminate the error cause,
then clear the error (Reset).

•

Are the signals to the intelligent
input terminals correct?

•

Is the Run Command active?

•

Is the [FW] terminal (or [RV])
connected to [PCS] (via switch,
etc.)

•

Verify the terminal functions
for C001 – C005 are correct.

•

Turn ON Run Command
enable.

•

Supply 24V to [FW] or [RV]
terminal, if configured.

•

Has the frequency setting for F001
been set greater than zero?

•

Are the control circuit terminals
[H], [O], and [L] connected to the
potentiometer?

•

Set the parameter for F001
to a safe, non-zero value.

•

If the potentiometer is the
frequency setting source,
verify voltage at [O] > 0V.

•

Is the RS (reset) function or FRS
(free-run stop) function ON?

•

Turn OFF the command(s).

Inverter outputs
[U], [V], [W]
are supplying
voltage.

•

Is the motor load too heavy?

•

Reduce load, and test the
motor independently.

The optional
remote operator
is used (SRW).

•

Are the operational settings
between the remote operator and
the inverter unit correct?

•

Check the operator type
setting.

The direction of the motor is

reversed.

•

Are the connections of output
terminals [U/T1], [V/T2], and
[W/T3] correct?

•

Is the phase sequence of the motor
forward or reverse with respect to
[U/T1], [V/T2], and [W/T3]?

•

Make connections according
to the phase sequence of the
motor. In general:
FWD = U-V-W, and
REV=U-W-V.

•

Are the control terminals [FW] and
[RV] wired correctly?

•

Is parameter F004 properly set?

•

Use terminal [FW] for
forward, and [RV] for
reverse.

•

Set motor direction in F004.