Hitachi L2002 User Manual

Page 92

Advertising
background image

“A” Group: Standard Functions

Configur

ing

Dr

iv

e P

a

ra

m

e

ters

3–12

The inverter has other control sources that can temporarily override the parameter A001
setting, forcing a different output frequency source. The following table lists all
frequency source setting methods and their relative priority (“1” is the highest priority).

The inverter also has other control sources that can temporarily override the parameter
A002 setting, forcing a different Run command source. The following table lists all Run
command setting methods and their relative priority (“1” is the highest priority).

Priority

A001 Frequency Source Setting Method

Refer to page...

1

[CF1] to [CF4] Multi-speed terminals

4–13

2

[OPE] Operator Control intelligent input

4–31

3

[F-TM] intelligent input

4–33

4

[AT] terminal

4–23

5

TM/PRG DIP Switch - (if switch is in “TM” position)

3–11

6

A001 Frequency source setting

3–10

Priority

A002 Run Command Setting Method

Refer to page...

1

[OPE] Operator Control intelligent input

4–31

2

[F-TM] intelligent input

4–33

3

TM/PRG DIP Switch - (if switch is in “TM” position)

3–11

4

A002 Run command source setting

3–10