B–43

The following table lists the holding registers for the “H” Group Motor Constants.

“H” Group Motor Constants

Func.

Code

Name

R/W

Description

Network Data

Register

Range

Res.

hex

dec.

H003

Motor capacity

R/W Thirteen selections:

0 .....0.20 kW
1 .....0.37 kW
2 .....0.40 kW
3 .....0.55 kW
4 .....0.75 kW
5 .....1.10 kW
6 .....1.50 kW
7 .....2.2 kW
8 .....3.0 kW
9 .....3.7 kW
10 ...4.0 kW
11 ...5.5 kW
12 ...7.5 kW

1165h

04453

0 to 12

H203

Motor capacity, 2nd
setting

R/W

1540h

05440

0 to 12

H004

Motor poles setting

R/W Four selections:

2 / 4 / 6 / 8

1166h

04454

2, 4, 6,

8

1 pole

H204

Motor poles setting, 2nd
motor

R/W

1541h

05441

2, 4, 6,

8

1 pole

H006

Motor stabilization
constant

R/W Motor constant (factory set),

range is 0 to 255

1168h

04456 0 to 255

1

H206

Motor stabilization
constant, 2nd motor

R/W

1543h

05443 0 to 255

1