Inverter Specifications

Getting Star

ted

1–8

Item

400V Class Specifications

L200

2

inverters,

400V models

EU types

004HFEF2

004HFE2

007HFEF2

007HFE2

015HFEF2

015HFE2

022HFEF2

022HFE2

USA type

004HFU2

007HFU2

015HFU2

022HFU2

Applicable motor size *2

kW

0.4

0.75

1.5

2.2

HP

1/2

1

2

3

Rated capacity (460V) kVA

1.1

1.9

2.9

4.2

Rated input voltage *6

3-phase: 380 to 480V ±10%, 50/60 Hz ±5%

Integrated EMC
filter

HFEF type

Three phase filter, Category C3 *5

HFE, HFU types

Rated input current (A)

2.0

3.3

5.0

7.0

Rated output voltage *3

3-phase: 380 to 480V (proportional to input voltage)

Rated output current (A)

1.5

2.5

3.8

5.5

Efficiency at 100% rated output (%)

93.5

94.0

95.3

95.7

Watt loss,
approximate (W)

at 70% output

20

30

45

65

at 100% output

26

42

70

95

Starting torque *7

100% at 6Hz

Braking

Dynamic
braking, approx.
% torque (short
time stop from
50 / 60 Hz) *8

50%:

≤ 60Hz

20%:

≤ 60Hz

Capacitive feedback type, dynamic braking unit and braking

resistor optional, individually installed

DC braking

Variable operating frequency, time, and braking force

Weight

HFEF type

kg

1.4

1.8

1.9

1.9

lb

3.09

3.97

4.19

4.19

HFE type

kg

1.3

1.7

1.8

1.8

lb

2.87

3.75

3.97

3.97

HFU type

kg

1.3

1.7

1.8

1.8

lb

2.87

3.75

3.97

3.97