Hitachi L2002 User Manual

Page 118

Advertising
background image

“B” Group: Fine Tuning Functions

Configur

ing

Dr

iv

e P

a

ra

m

e

ters

3–38

“B” Function

Run

Mode

Edit

Lo Hi

Defaults

Func.

Code

Name /

SRW Display

Description

–FE(F)

(EU)

–FU

(USA)

Units

B021 Overload restriction

operation mode

Select the operating mode
during overload conditions,
three options, option codes:
00... Disabled
01... Enabled for acceleration
and constant speed
02... Enabled for constant
speed only

✘ ✔

01

01

OL Mode ON

B221 Overload restriction

operation mode, 2nd
motor

✘ ✔

01

01

2OL Mode ON

B022 Overload restriction

setting

Sets the level for overload
restriction, between 10% and
150% of the rated current of
the inverter, setting resolution
is 1% of rated current. This
parameter monitors (read-only)
the [O]–[L] input when that
input is the overload restriction
source (B028/B228 = 01).

✘ ✔

Rated current x

1.5

A

OL LVL 002.40A

B222 Overload restriction

setting, 2nd motor

✘ ✔

Rated current x

1.5

A

2OL LVL 002.40A

B023 Deceleration rate at

overload restriction

Sets the deceleration rate when
inverter detects overload, range
is 0.1 to 30.0, resolution is 0.1.

✘ ✔

1.0

30.0

sec.

OL Cnst 0001.0s

B223 Deceleration rate at

overload restriction,
2nd motor

Sets the deceleration rate when
inverter detects overload, range
is 0.1 to 30.0, resolution is 0.1.

✘ ✔

1.0

30.0

sec.

2OL Cnst 0001.0s

B028 Overload restriction

source selection

Two options; select codes:
00... B022/B222 setting level
01... [O]–[L] analog input

✘ ✔

00

00

sec.

OL L-Slct C022

B228 Overload restriction

source selection, 2nd
motor

Two options; select codes:
00... B022/B222 setting level
01... [O]–[L] analog input

✘ ✔

00

00

sec.

2OL L-Slct C022