“P” Group: Expansion Card Functions

Configur

ing

Dr

iv

e P

a

ra

m

e

ters

3–64

“P” Group: Expansion Card Functions

The (optional) expansion card for the L200

2

inverter has assiciated configuration data.

The following table defines the functions and their value ranges. Please refer to the
expansion card manual for more details.

NOTE: The “P” Group parameters do not appear in the parameter list shown on the
keypad display unless the expansion card is installed on the inverter.

“P” Function

Run

Mode

Edit

Lo Hi

Defaults

Func.

Code

Name /

SRW Display

Description

–FE(F)

(EU)

–FU

(USA)

Units

P044

Network comm
watchdog timer

Range is 0.00 to 99.99

✘ ✘

1.00

1.00

sec.

TIMER 01.00s

P045

Inverter action on
network comm error

Five options:
00... Trip (Error Code E70)
01... Decelerate to stop and trip
(Error Code E70)
02... Hold last speed
03... Free run stop
04... Decelerate and stop

✘ ✘

01

01

T-OUT FTP

P046

Polled I/O output
instance number

Three settings:
20, 21, 100

✘ ✘

21

21

O-AS-INS 021

P047

Polled I/O input
instance number

Three settings:
70, 71, 101

✘ ✘

71

71

O-AS-INS 071

P048

Inverter action on
network idle mode

Five options:
00... Trip (Error Code E70)
01... Decelerate to stop and trip
(Error Code E70)
02... Hold last speed
03... Free run stop
04... Decelerate and stop

✘ ✘

01

01

IDLE FTP

P049

Network motor poles
setting for RPM

Range is 00 to 38 (even
numbers only)

✘ ✘

0

0

P 00P