B–16, Appendix b – Hitachi L2002 User Manual

Page 252

Advertising
background image

Network Protocol Reference

Appendix B

B–16

Writing in Holding Registers [10h]:

This function writes data in consecutive holding registers. An example follows:

• Write “3000 seconds” as the first acceleration time 1 (F002) in an inverter having a

slave address “1.”

• This example uses change data “300000(493E0h)” to set “3000 seconds” as the data

resolution of the registers “0024h” and “0025h” holding the first acceleration time 1
(F002) is 0.01 second.

When writing in selected holding registers fails, see the exception response.

Query:

Note 1:

Broadcasting is disabled.

Note 2:

This is not the number of
holding registers. Specify the
number of bytes of data to be
changed.

Response:

No.

Field Name

Example

(Hex)

1

Slave address *1

01

2

Function code

10

3

Start address (high
order)

00

4

Start address (low
order)

24

5

Number of holding
registers (high order)

00

6

Number of holding
registers (low order)

02

7

Byte number *2

04

8

Change data 1
(high order)

00

9

Change data 1
(low order)

04

10

Change data 2
(high order)

93

11

Change data 2
(low order)

E0

12

CRC-16 (high order)

DC

13

CRC-16 (low order)

FD

No.

Field Name

Example

(Hex)

1

Slave address

01

2

Function code

10

3

Start address (high
order)

00

4

Start address (low
order)

24

5

Number of holding
registers (high order)

00

6

Number of holding
registers (low order)

02

7

CRC-16 (high order)

01

8

CRC-16 (low order)

C3

Advertising