NOTE: When setting function A039 = 01, the actual jogging deceleration time depends
on the standard Deceleration Time Setting F003/F203.

“A” Function

Run

Mode

Edit

Lo Hi

Defaults

Func.

Code

Name /

SRW Display

Description

–FE(F)

(EU)

–FU

(USA)

Units

A020 Multi-speed frequency

setting

Defines the first speed of a
multi-speed profile, range is
0.0 / start frequency to 400 Hz
A020 = Speed 0 (1st motor)

✔ ✔

0.0

0.0

Hz

SPD 00s 0000.0Hz

A220 Multi-speed frequency

setting, 2nd motor

Defines the first speed of a
multi-speed profile for 2nd
motor, range is 0.0 / start
frequency to 400 Hz
A220 = Speed 0 (2nd motor)

✔ ✔

0.0

0.0

Hz

2SPD00s 0000.0Hz

A021

to

A035

Multi-speed frequency
settings
(for both motors)

Defines 15 more speeds,
range is 0.0 / start frequency
to 400 Hz.
A021= Speed 1...
A035 = Speed 15

✔ ✔

see

next

row

see

next

row

Hz

SPD 01s 000.0Hz
SPD 02s 000.0Hz
SPD 03s 000.0Hz
SPD 04s 000.0Hz
SPD 05s 000.0Hz
SPD 06s 000.0Hz
SPD 07s 000.0Hz
SPD 08s 000.0Hz
SPD 09s 000.0Hz
SPD 10s 000.0Hz
SPD 11s 000.0Hz
SPD 12s 000.0Hz
SPD 13s 000.0Hz
SPD 14s 000.0Hz
SPD 15s 000.0Hz

A021
A022
A023
A024
A025
A026
A027
A028
A029
A030
A031
A032
A033
A034
A035

0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0

0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0

A038 Jog frequency setting

Defines limited speed for jog,
range is 0.00 / start frequency
to 9.99 Hz

✔ ✔

1.00

1.00

Hz

Jog-F 001.00Hz

A039 Jog stop mode

Define how end of jog stops
the motor; three options:
00 .. Free-run stop
01 .. Controlled deceleration
02 .. DC braking to stop

✘ ✔

00

00

Jog-Mode FRS