Getting star ted – Hitachi L2002 User Manual

Page 27

Advertising
background image

L200

2

Inverter

Getting Star

ted

1–7

L200

2

Inverter Specifications, continued...

Item

200V Class Specifications, continued

L200

2

inverters,

200V models

EU types

015NFEF2

015NFE2

022NFEF2

022NFE2

—

—

—

USA type

015NFU2

022NFU2

037LFU2

055LFU2

075LFU2

Applicable motor size *2

kW

1.5

2.2

3.7

5.5

7.5

HP

2

3

5

7.5

10

Rated capacity
(kVA)

230V

2.8

3.9

6.3

9.5

12.7

240V

2.9

4.1

6.6

9.9

13.3

Rated input voltage

1-phase: 200 to 240V ±10%, 50/60 Hz ±5%,
3-phase: 200 to 240V ±10%, 50/60 Hz ±5%,

(037LFU2, 055LFU2, 075LFU2 3-phase only)

Integrated EMC
filter

NFEF type

Single phase filter,

Category C3 *5

—

NFE, NFU types

—

Rated input
current (A)

1-phase

16.0

22.5

—

—

—

3-phase

9.3

13.0

20.0

30.0

40.0

Rated output voltage *3

3-phase: 200 to 240V (proportional to input voltage)

Rated output current (A)

7.1

10.0

15.9

24

32

Efficiency at 100% rated output (%)

96.3

95.5

95.4

95.6

96.0

Watt loss,
approximate (W)

at 70% output

39

62

110

175

210

at 100% output

55

98

170

244

300

Starting torque *7

100% at 6Hz

Braking

Dynamic
braking, approx.
% torque (short
time stop from
50 / 60 Hz) *8

50%:

≤ 60Hz

20%:

≤ 60Hz

Capacitive feedback type, dynamic braking unit and braking

resistor optional, individually installed

DC braking

Variable operating frequency, time, and braking force

Weight

NFEF type

kg

1.9

1.9

—

—

—

lb

4.2

4.2

—

—

—

NFE type

kg

1.8

1.8

—

—

—

lb

3.97

3.97

—

—

—

NFU type

kg

1.8

1.8

1.9

5.5

5.7

lb

3.97

3.97

4.2 12.13

12.57

Advertising