Accel/decel – Hitachi L2002 User Manual

Page 108

Advertising
background image

“A” Group: Standard Functions

Configur

ing

Dr

iv

e P

a

ra

m

e

ters

3–28

Accel/Decel

Standard acceleration and deceleration is
linear. The inverter CPU can also calculate
an S-curve acceleration or deceleration
curve as shown. This profile is useful for
favoring the load characteristics in particu-
lar applications.

Curve settings for acceleration and decel-
eration are independently selected. To
enable the S-curve, use function A097
(acceleration) and A098 (deceleration).

Acceleration period

S-curve

Linear

Accel. curve selection

Target

freq.

Output

frequency

t

0

A097 = 00

A097 = 01

“A” Function

Run

Mode

Edit

Lo Hi

Defaults

Func.

Code

Name /

SRW Display

Description

–FE(F)

(EU)

–FU

(USA)

Units

A097 Acceleration curve

selection

Set the characteristic curve of
Acc1 and Acc2, two options:
00... linear
01... S-curve

✘ ✘

00

00

ACC LINE L

A098 Deceleration curve

selection

Set the characteristic curve of
Acc1 and Acc2, two options:
00... linear
01... S-curve

✘ ✘

00

00

DEC LINE L

Advertising