Trip Event and History Monitoring

The trip event and history monitoring feature lets you cycle through related information
using the keypad. See

“Monitoring Trip Events, History, & Conditions” on page 6–5

for

more details.

D007 Scaled output frequency

monitor

Displays the output frequency
scaled by the constant in B086.
Decimal point indicates range:
XX.XX 0.00 to 99.99
XXX.X 100.0 to 999.9
XXXX. 1000. to 9999.
XXXX 1000 to 9999 (x10=
10000 to 99999)

Hz times

constant

F-Cnv 00000.00

D013 Output voltage monitor

Voltage of output to motor,
range is 0.0 to 600.0V

V

Vout 00000V

D016 Cumulative operation

RUN time monitor

Displays total time the inverter has
been in RUN mode in hours.
Range is 0 to 9999 /
1000 to 9999 /

Γ100 to Γ999 (10,000 to 99,900)

hours

RUN 0000000hr

D017 Cumulative power-on

time monitor

Displays total time the inverter has
been in RUN mode in hours.
Range is 0 to 9999 /
1000 to 9999 /

Γ100 to Γ999 (10,000 to 99,900)

hours

ON 0000000hr

“D” Function

Run

Mode

Edit

Units

Func.

Code

Name /

SRW Display

Description

“D” Function

Run

Mode

Edit

Units

Func.

Code

Name /

SRW Display

Description

D080 Trip counter

Number of trip events,
range is 0. to 9999

events

ERR CNT 00000

D081 Trip monitor 1

Displays trip event informa-
tion:

Error code

Output freq. at trip point

Motor current at trip point

DC bus voltage at trip point

Cumulative inverter opera-
tion time at trip point

Cumulative power-ON time
at trip point

ERR 1 ########

D082 Trip monitor 2

ERR 2 ########

D083 Trip monitor 3

ERR 3 ########