Introduction

Appendix C

C–2

Introduction

This appendix lists the user-programmable parameters for the L200

2

series inverters and

the default values for European and U.S. product types. The right-most column of the
tables is blank, so you can record values you have changed from the default. This
involves just a few parameters for most applications. This appendix presents the parame-
ters in a format oriented toward the keypad on the inverter.

Parameter Settings for Keypad Entry

L200

2

series inverters provide many functions and parameters that can be configured by

the user. We recommend that you record all parameters that have been edited, in order to
help in troubleshooting or recovery from a loss of parameter data.

Main Profile Parameters

}

This information is printed
on the specification label
located on the right side of
the inverter.

L200

2

Inverter model

MFG. No.

“F” Group Parameters

Default Setting

User

Setting

Func.

Code

Name

–FE(F)

(Europe)

–FU

(USA)

F001

Output frequency setting

0.0

0.0

F002

Acceleration (1) time setting

10.0

10.0

F202

Acceleration (1) time setting, 2nd
motor

10.0

10.0

F003

Deceleration (1) time setting

10.0

10.0

F203

Deceleration (1) time setting, 2nd
motor

10.0

10.0

F004

Keypad Run key routing

00

00