Options, Caution – general safety hazard – Teledyne 9110TH - Nitrogen Oxides Analyzer User Manual

Page 22

Advertising
background image

Model 9110TH NOx Analyzer

Introduction

Teledyne Analytical Instruments

2

1.4. OPTIONS

Option

Option
Number

Description/Notes Reference

Pumps

Pumps meet all typical AC power supply standards while exhibiting same
pneumatic performance.

11A Ship

without

pump

N/A

11B

Pumpless Pump Pack

N/A

12A

Internal Pump 115V @ 60 Hz

N/A

12B

Internal Pump 220V @ 60 Hz

N/A

12C

Internal Pump 220V @ 50 Hz

N/A

Rack Mount
Kits

Options for mounting the analyzer in standard 19” racks

20A

Rack mount brackets with 26 in. (660 mm) chassis slides

N/A

20B

Rack mount brackets with 24 in. (610 mm) chassis slides

N/A

21

Rack mount brackets only (compatible with carrying strap, Option 29) N/A

23

Rack mount for external pump pack (no slides)

N/A

Carrying Strap/Handle

Side-mounted strap for hand-carrying analyzer

29

Extends from “flat” position to accommodate hand for carrying.
Recesses to 9mm (3/8”) dimension for storage.
Can be used with rack mount brackets, Option 21.
Cannot be used with rack mount slides.

N/A

CAUTION – GENERAL SAFETY HAZARD

THE 9110TH OR 9110TM ANALYZER WEIGHS ABOUT 18 KG (40 POUNDS).

TO AVOID PERSONAL INJURY WE RECOMMEND THAT TWO PERSONS LIFT AND CARRY THE

ANALYZER. DISCONNECT ALL CABLES AND TUBING FROM THE ANALYZER BEFORE MOVING IT.

Analog Input and USB port

Used for connecting external voltage signals from other instrumentation (such as
meteorological instruments).

64B

Also can be used for logging these signals in the analyzer’s internal
DAS

Section 3.4.2

Current Loop Analog
Outputs

Adds isolated, voltage-to-current conversion circuitry to the analyzer’s analog
outputs.

41

Can be configured for any output range between 0 and 20 mA.
May be ordered separately for any of the analog outputs.
Can be installed at the factory or retrofitted in the field.

Section 3.4.5

Parts Kits

Spare parts and expendables

42A

Expendables Kit includes a recommended set of expendables for
one year of operation of this instrument including replacement
sample particulate filters.

Appendix B

Calibration Valves

Used to control the flow of calibration gases generated from external sources,
rather than manually switching the rear panel pneumatic connections.

50A

AMBIENT ZERO AND AMBIENT SPAN VALVES

Zero Air and Span Gas input supplied at ambient pressure.
Gases controlled by 2 internal valves; SAMPLE/CAL & ZERO/SPAN.

Section 3.5.3.1

50D

ZERO SCRUBBER AND DUAL PRESSURIZED SPAN VALVES

Zero Air Scrubber produces/supplies zero air to the ZERO inlet port.
Dual Pressurized Span Valves for two gas mixtures to separate inlet ports,

HIGH SPAN and LOW SPAN

.

Section 3.5.3.2