Drive Enable Output

The +/- Axis Enable is a signal from the 1394 system module that is
used to control a DPDT relay in the 1394-DIM. This enable output is
a normally open, unpowered (dry) signal.

Figure 4.27
Drive Enable Output

Analog Output

The analog output is an isolated signal provided by the 1394-DIM and
has a range of ±10V. The signal is either a torque or velocity
command, depending on the configuration of the remote drive. The
command is processed by the Bulletin 1394 System Module through a
12-bit Digital-Analog Converter (DAC). An output offset of ±80 mV
can be compensated to 0V through software configuration.

Figure 4.28
Analog Output

For additional DIM signal descriptions refer to Appendix A.

P

x-4

P

x-3

Axis Enable+

Axis Enable-

1394-DIM

Normally
Open Relay

Note:

x = axis connector number

P

x-1

P

x-2

Axis OUT+

Axis OUT-

1394-DIM

Note:

x = axis connector number

Advertising