Encoder feedback wiring – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 90

Advertising
background image

Publication 1394-5.0 — May 2000

4-10

Wiring 1394 GMC and GMC Turbo Systems

Encoder Feedback Wiring

These connectors accept encoder feedback signals from an optional
encoder. Terminal 10 requires a user-supplied, regulated +5V DC
(

±

5%). We recommend Belden #9728 wire or equivalent. When you

use a 5 volt power supply, there is a maximum distance between the
encoder and 1394 of 12.2 meters (40 feet).

The 1394 interface circuitry requires 0.325A to operate. Any
additional devices connected to the 1394, such as incremental
encoders, may require an additional 0.2A per device to operate.
Check your device for operational requirements.

Make the encoder feedback connections according to the table below.
Connectors are located on the bottom of your system module (refer to
Figure 4.7 for 1394x-SJTxx-C and -T systems and Figure 4.8 for
1394C-SJTxx-L systems).

To improve the bond between the motor feedback cable shield and the
system module PE ground, a cable shield clamp is included with the
Series C system modules.

Ensure an appropriate amount of the cable insulation and braided
shield is removed from the feedback cable. Place the cable wires and
exposed braided shield into the cable shield clamp and tighten the
clamp screw. Then thread the bracket screw into the bottom of the
system module and tighten. Refer to the figure below for an
illustration.

Figure 4.9
Series C System Module Cable Clamps

For this axis: Connect to this terminal:

0

J3

1

J4

2

J5

3

J10

1394 front view

System module

ground bar

Feedback

cable clamps

Cable Preparation

Clamp Attachment

Wiring to System Module

Cable wires

Braided
shield
exposed

Cable
shield

clamp

Motor

cable

Clamp

screw

Bracket

screw

51 mm

(2.0 in.)

1

22 mm

(.875 in.)

1

Dimensions given are approximate and will vary
depending on the specific installation. Keep wires
as short as possible while maintaining adequate
stress relief.

1