Publication 1394-5.0 — May 2000

Configuring Your 1394 Analog Servo System

8-11

[Droop]

This parameter is also referred to as "static gain."
It effectively acts as a very slow discharge of the
velocity loop integrator and has two uses:

As a component of an external position loop
system, setting this parameter to a higher, non-
zero value will eliminate servo hunting due to
load stick/slip friction effects.

As a deliberate "velocity droop" (secondary
drives only) in multiple-motor systems where
each drive axis is configured as a velocity loop
and the motors are mechanically coupled
together. Use of higher non-zero droop in this
case promotes load sharing.This parameter
selects the torque command source within the
drive. When operating the drive in velocity
mode, set to Velocity Mode 1 (#0). When
operating in torque mode (using S Class), set
to A/D Torque Block (#4).

This parameter selects the torque command
source within the drive. When operating the drive
in velocity mode, set to Velocity Mode 1 (#0).
When operating in torque mode (using S Class),
set to A/D Torque Block (#4).
The droop scaling is defined as that specified
droop in output rpm (i.e., velocity error) that will
result in 100% rated torque being applied by the
motor in reaction. This parameter only has effect
if [Intg Gain Ki] is not zero.
For Example: Speed regulation of 0 to 0.05%
maximum depending on optimization of system
performance settings. 3000 rpm, 0.05% = 1.5
rpm tolerance.

Parameter Numbers

380, 381, 382, 383

Parameter Group

Vel Loop Data

Display Units

rpm

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

0.0 rpm (No Droop)

Maximum Value

15.6 rpm

Default Value

1.0 rpm

[Enabled Days]

Displays the number of days that the drive has
been enabled.

Parameter Numbers

93

Parameter Group

Linear List

Display Units

None

Parameter Type

Read Only

Linkable

No

[Enabled Minutes]

Displays the number of minutes that the drive has
presently been enabled.

Parameter Numbers

92

Parameter Group

Linear List

Display Units

None

Parameter Type

Read Only

Linkable

No

[Fdbk Pole Cnt]

The number of electrical poles on the resolver.

Note: Before making modifications to Mtr Data
parameters, [Motor Type] must be set to "custom
motor".

Parameter Numbers

400

Parameter Group

Mtr Data

Display Units

None

Parameter Type

Read/Write

Change While Running

No

Linkable

No

Minimum Value

2

Maximum Value

8

Default Value

This is determined by the motor catalog number.