Publication 1394-5.0 — May 2000

Configuring Your 1394 Analog Servo System

8-15

[Mod Rng Data]

Diagnostic information of data communicated
between the controller and Axis Module.

Parameter Numbers

196, 197, 198, 199

Parameter Group

Linear List

Parameter Type

Read Only

[Mode Sel]

This parameter modifies both [Vel Source] and
[Torq Source] to appropriate value based on
selection (for convenience during
commissioning).

Parameter Numbers

112, 113, 114, 115

Parameter Group

Configuration, Startup Parms

Display Units

None

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Default Value

0

"Anlg Vel"

Selections

0

"Anlg Vel"

1

"Ana Torq"

2

"Dig Vel"

3

"Dig Torq"

[Module Size]

Current rating of the Axis Module. This is set after
the initialization of the 1394 Analog Servo
System DSP.

Parameter Numbers

324, 325, 326, 327

Parameter Group

Torq Data

Display Units

amps

Parameter Type

Read Only

Linkable

No

Bit 15

Bit 14

Bit 13

Bit 12

Bit 11

Bit 10

Bit 9

Bit 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Control
Read/Write

Axis Enabled

Version of axis
module EPLD

Scaling Bit

Size Bit

Ovr Temp Flt

Bus Loss Warning

I(t) Fault

Power Fault

Size Bit

Size Bit

Size Bit

Scaling Bit

Scaling Bit

Scaling Bit