5-6

Wiring Your 1394 Analog Servo System

Make the A Quad B connections at the bottom of the system module
(refer to Figure 5.3) as follows:

To improve the bond between the motor feedback cable shield and the
system module PE ground, a cable shield clamp is included with the
Series C system modules.

Ensure an appropriate amount of the cable insulation and braided
shield is removed from the feedback cable. Place the cable wires and
exposed braided shield into the cable shield clamp and tighten the
clamp screw. Then thread the bracket screw into the bottom of the
system module and tighten. Refer to the figure below for an
illustration.

Figure 5.4
Series C System Module Cable Clamp

For this axis:

Connect to this terminal:

0

AQB0

1

AQB1

2

AQB2

3

AQB3

1394 front view

System module

ground bar

Feedback

cable clamps

Cable Preparation

Clamp Attachment

Wiring to System Module

Cable wires

Braided
shield
exposed

Cable
shield

clamp

Motor

cable

Clamp

screw

Bracket

screw

51 mm

(2.0 in.)

1

22 mm

(.875 in.)

1

Dimensions given are approximate and will vary
depending on the specific installation. Keep wires
as short as possible while maintaining adequate
stress relief.

1