Publication 1394-5.0 — May 2000

Configuring Your 1394 Analog Servo System

8-23

[Sys Mod Data]

Diagnostic information of data communicated
between the controller and system module.

Parameter Numbers

6

Parameter Group

Linear List

Parameter Type

Read Only

[Sys Mod Status 2]

Diagnostic information of smart power systems.

Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems

1 = true
Note: Warnings are set at 80% rating.

Parameter Numbers

38

Parameter Group

Linear List

Parameter Type

Read Only

[System Type]

Catalog number of System Module. Set during
the initialization of the 1394

x-SJTxx-A system

module.

Parameter Numbers

14

Parameter Group

Configuration

Display Units

None

Parameter Type

Read Only

Linkable

No

0

"NOT PRESENT"

1

"1394

x-SJT05"

2

"1394

x-SJT10"

3

"1394-SJT22"

[Test Mode Sel]

Internal (factory) test mode selections.

Parameter Numbers

16

Parameter Group

Linear List

Display Units

None

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

0

Maximum Value

32767

Default Value

0

Bit 15

Bit 14

Bit 13

Bit 12

Bit 11

Bit 10

Bit 9

Bit 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Version Bits

Ctrl Pwr Loss

Ovr Temp Flt

Bus Undr Vlt

Bus 0V Flt

Phs Loss Flt

Ground Fault

Size Bit

Not Used

Size Bit

Size Bit

Size Bit

Bit 15

Bit 14

Bit 13

Bit 12

Bit 11

Bit 10

Bit 9

Bit 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

CurLim Fault

Shunt Warn

Ctrl Pwr Loss

Ovr Temp Flt

Bus Undr Vlt

Bus 0V Fault

Phs Loss Flt

Ground Fault

Shunt Fault

CurLim Warn

Not Used

PreCharge Fault