Remote i/o adapter specifications – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 213

Advertising
background image

Publication 1394-5.0 — May 2000

Specifications

A-15

Remote I/O Adapter Specifications

The table below lists the remote I/O adapter specifications for the
system module (1394x-SJTxx-C-xx, -L-xx, and -T-xx systems).

The:

Is:

Baud rate

57.6 k, 115.2 k, or 230.4 k (user-selectable)

Rack address

User-selectable between 0 and 31 decimal

Rack width

User-selectable in quarter-rack increments (1/4, 1/2, 3/4, or full)

Transfer type

I/O Group

Block

0 2 4 6

0 2 4

0 2

0

Discrete

1 3 5 7

1 3 5

1 3

1

Discrete

2 4 6

2 4

2

Discrete

3 5 7

3 5

3

Discrete

4 6

4

Discrete

5 7

5

Discrete

6

Discrete

7

Starting I/O group

0 2 4 6

0 2 4

0 2

0

Rack width

1/4

1/2

3/4

full

Number of discrete I/O bits • 12 dedicated inputs

• 12 dedicated outputs
• 1/4 rack width with 4 inputs and 4 outputs
• 1/2 rack width with 36 inputs and 36 outputs
• 3/4 rack width with 68 inputs and 68 outputs
• Full rack width with 100 inputs and 100 outputs

Maximum block transfer
length

64 words (128 bytes)

Block transfer data types

• User variable values
• Axis data parameter value
• Axis data bit state
• Master cam position point values
• Master cam time point values
• Slave cam position point values
• Axis or system variable value

Block transfer data formats • 32-bit (double-word) 2s compliment integer

• 16-bit (single-word) 2s compliment integer
• 32-bit (8-digit) signed BCD
• 32-bit IEEE floating point
• Word-swapped 32-bit (double-word) 2s compliment integer
• Word-swapped 32-bit (8-digit) signed BCD
• Word-swapped 32-bit IEEE floating-point

Advertising
This manual is related to the following products: