Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 170

Advertising
background image

Publication 1394-5.0 — May 2000

9-4

Troubleshooting

For this module:

For this LED:

Status of the
LED:

Potential Cause:

Possible resolution:

Axis Module

Status

Steady red

Malfunctioning axis module.

• Verify wiring.
• Verify that the slider and terminator are

securely engaged.

• Secure wiring connections.
• Replace the module.

Flashing red

Axis fault has occurred.

• Verify wiring.
• Secure wiring connections.
• Check fault status on the HIM (Analog

Servo only), in GML (GMC only), or on the
operator panel (CNC Interface and 9/440).

• Check 460V AC input power.
• Check axis status on the HIM (Analog

Servo only), in GML (GMC only), and on
the operator panel (CNC Interface and
9/440)

Alternating
red and
green

DC bus is not up.

• Check the system module’s LED.
• Check slider connections to verify that they

are properly seated.

• Verify that the terminator is present on the

last axis.

Flashing
green

Axis is not enabled.

• Check axes and enable them, if necessary.
• Verify that enable wiring is correct and not

open.

Enable signal from position
controller is not present (Analog
Servo only).

• Check axes and enable them, if necessary.
• Verify that enable wiring is correct and not

open.

Incorrect wiring or loose
connections.

Check connections on the input wiring board.

Axis setups may not be correct for
the application.

• Verify that axis definitions are correct.
• Check tuning parameters.

Not
illuminated

There is no power to the axis
module.

Verify that the terminator is present on the last
axis.

There is no power to the system.

• Verify that the terminator is present on the

last axis.

• Check system module power supply.

Advertising