Shunt p, Shunt peak usage, Shunt r – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 156: Shunt type, Shunt usage

Advertising
background image

Publication 1394-5.0 — May 2000

8-20

Configuring Your 1394 Analog Servo System

[Shunt P]

Shunt resistor continuous power rating.

Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.

This parameter only needs to be configured
when you are using custom resistors.

Note: [Shunt Type] must be set to "custom shunt"
before making modifications to this shunt
parameter (44-48).

Parameter Numbers

45

Parameter Group

Linear List

Display Units

Watts

Parameter Type

Read/Write

Change While Running

No

Minimum Value

100

Maximum Value

22000

Default Value (22 kW)

900

Default Value (5 and 10 kW)

200

[Shunt Peak Usage]

This parameter shows the peak usage of the
shunt resistor over the last ten seconds. (%) This
parameter can be observed to determine
proximity of usage to fault condition. Warning is
set at 80%. Fault is set when value reaches
105%.

Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.

Parameter Numbers

51

Parameter Group

Smart Sys Data

Display Units

%

Parameter Type

Read Only

Linkable

No

[Shunt R]

Shunt resistor resistance. Set this parameter
only when using a custom resistor.

Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.

Note: [Shunt Type] must be set to "custom shunt"
before making modifications to this shunt
parameter (44-48).

Parameter Numbers

44

Parameter Group

Linear List

Display Units

Ohms

Parameter Type

Read/Write

Change While Running

No

Minimum Value

4 (22kW systems)
16 (5 and 10 kW systems)

Maximum Value

255

Default Value

Set by [Shunt Type]

[Shunt Type]

Selects shunt module model number or type.

Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.

Note: [Shunt Type] must be set to "custom shunt"
before making modifications to associated shunt
parameters (44-48).

Parameter Numbers

43, 49

Parameter Group

Linear List

Display Units

None

Parameter Type

Read/Write

Change While Running

No

Linkable

No

Default Value

1 "1394-SR-9A"

(22

kW

systems)

6

"Internal" (5 and 10 kW systems)

Selections

0

"Custom Shunt"

1

"1394-SR-9A"

2

"1394-SR-9AF"

3

"1394-SR-36A"

4

"1394-SR-36AF"

5

"1394-SR-10A"

6

"Internal" (5 and 10 kW systems)

[Shunt Usage]

% of shunt power used.

Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.

Parameter Numbers

42

Parameter Group

Smart Sys Data

Display Units

%

Parameter Type

Read Only

Linkable

No