Finding analog servo system faults, Finding 9/440 faults – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 173

Advertising
background image

Publication 1394-5.0 — May 2000

Troubleshooting

9-7

Finding Analog Servo System Faults

When a fault occurs for the Analog Servo version, a fault message
appears on the HIM.

Figure 9.1
HIM Fault Display

Each area on the diagram in Figure 9.1 has a significance:

Finding 9/440 Faults

Faults for the 9/440 appear on the second line of the operator panel.
There is also an error log that contains the most recent system faults.
To get to this error log screen:

1. At the main menu, press the continue softkey. The softkey menu

changes.

2. Press the {ERROR MESAGE} softkey. The error message screen

appears.

For more information on 9/440 system faults refer to the 9/Series
Integration and Maintenance Manual
(catalog 8520-6.2).

Fault Number

Fault Name

Hard Fault Indicator

Source of Fault

In this area:

This information appears:

Source of fault

The area in which the fault originated:
Ax0 = Axis module 0
Ax1 = Axis module 1
Ax2 = Axis module 2
Ax3 = Axis module 3
Sys = System module
CPU = The host CPU (hardware)
DSP = DSP CPU (hardware
Cus. = User action is the source of the fault
Hdw. = Drive hardware is the source of the fault

Fault name

An abbreviated message indicating a particular fault.

Hard fault indicator

If an exclamation point appears in this location, a hard
fault has occurred. You need to cycle drive power to
clear this type of fault.

Fault number

The number associated with the particular fault.

Advertising
This manual is related to the following products: