Shunt ws, Slot 0 opt. card, Software version – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 157: Startup state, State, Status display

Advertising
background image

Publication 1394-5.0 — May 2000

Configuring Your 1394 Analog Servo System

8-21

[Shunt Ws]

Shunt short time constant weighting factor. This
parameter determines the relationship between
the short and long time constants in the thermal
model of the shunt module. The long time
constant weighting factor is 100% - Ws%.
Configure this parameter only when a custom
resistor is selected.

Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.

Note: [Shunt Type] must be set to "custom shunt"
before making modifications to associated shunt
parameters (44-48).

Parameter Numbers

48

Parameter Group

Linear List

Display Units

%

Parameter Type

Read/Write

Change While Running

No

Minimum Value

1

Maximum Value

100

Default Value

100

[Slot 0 Opt. Card]

Description of adapter card in option slot.

Parameter Numbers

5

Parameter Group

Linear List

Display Units

None

Parameter Type

Read Only

Linkable

No

Selections

0

"No Opt Instd"

[Software Version]

Numeric value of software version.

Parameter Numbers:

1

Parameter Group:

Configuration

Parameter Type:

Read Only

Linkable

No

[Startup State]

Present state value of the startup procedure.

Parameter Numbers

3

Parameter Group

Linear List

Display Units

None

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

0

Maximum Value

100

Default Value

1

[State]

Present state of axis module; enabled/disabled.

Parameter Numbers

200, 201, 202, 203

Parameter Group

Linear List

Display Units

None

Parameter Type

Read Only

Linkable

No

Selections

0

"Disabled"

1

"Enabled"

[Status Display]

Textual description of present status of drive.

Parameter Numbers

8

Parameter Group

Linear List

Display Units

None

Parameter Type

Read Only

Linkable

No

Selections

0

"Sys Faulted"

1

"Sys Wait Bus"

2

"Sys Bus Chrg"

3

"Sys Ready"

4

"Sys Enabled"

5

"Sys Stopping"

Advertising