Conventions used in this chapter – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 138

Advertising
background image

Publication 1394-5.0 — May 2000

8-2

Configuring Your 1394 Analog Servo System

Conventions Used in this Chapter

The following conventions are used throughout this chapter.

All parameters required for any given drive function are
contained within a group, eliminating the need to change groups
to complete a function.

Each parameter will contain the following:

Note: To determine the series of your module, refer to Figure P.1 in

the Preface.

Parameter:

Description:

Name

The actual parameter name as displayed on the HIM (or ODS
software). Parameter names appear within brackets, for example:
[100% Torq Vel].

Description

An explanation of the parameter and, when feasible, an application
example.

Number

Each parameter is assigned a number that can be used for serial
communication. The numbers are listed in order for Axis 0, 1, 2, 3.

Group

Most parameters are contained in a group to make programming
easier.

Display Units

• ENUMS - A language statement pertaining to the selection made.

• Engineering - Standard display units such as; Hz, sec, volts, etc.

• Drive Units - These are internal Display Units used to communicate

through the serial port, and to scale values properly when reading
or writing to the drive.

Type

• Read Only - The value is changed only by the drive and is used to

monitor values.

• Read/Write - The value is changed through programming. This type

can also be used to monitor a value.

Change While
Running

States whether the parameter can be changed while the drive is
running.

Linkable

States whether the parameter can be linked.

Minimum Value

This is the lowest setting possible for parameters.

Maximum Value

This is the highest setting possible for parameters.

Default Value

This is the value assigned to each parameter at the factory. It is also
the value that will be restored if you choose to restore defaults from
the HIM. Display text appears within quotation marks.

Selections

Predefined functions. Display text appears within quotation marks.

Advertising
This manual is related to the following products: