8-26

Configuring Your 1394 Analog Servo System

[Enble Input Mode]

This parameter specifies whether the hardware
enable signals are used on the wiring board for
input. If configured as Not Used, the HIM or
SCANport device will provide the enable signal
for the axis.

Parameter Numbers

24

Parameter Group

Setup

Display Units

None

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Default Value

0

"Used"

Selections

0

"Used"

1

"Not Used"

[Vel Command]

Present velocity command for the axis (after all
limiting has occurred).

Parameter Numbers

220, 221, 222, 223

Parameter Group

Monitor Parms, Vel Cmd Data

Display Units

rpm

Parameter Type

Read Only

Linkable

No

[Vel Damp Sel]

This parameter is associated with the auto tune
function and specifies the velocity damping
desired by the user. The auto tuning procedure
calculates a new set of Velocity Loop Gains and
a new Current Rate Limit when the user initiates
the Auto Tune Calculate function.

Parameter Numbers

256, 257, 258, 259

Parameter Group

ATune Config

Display Units

None

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Default Value

0

"Zeta=0.87"

Selections

0

"Zeta=0.87"

Underdamped

1

"Zeta=1.00"

Critically Damped

2

"Zeta=0.70"

Underdamped

3

"Zeta=1.40"

Overdamped

[Vel Feedback]

Present velocity feedback for the axis (after all
filtering has occurred).

Parameter Numbers

224, 225, 226, 227

Parameter Group

Monitor Parms, Vel Cmd Data

Display Units

rpm

Parameter Type

Read Only

Linkable

No

[Vel Lim]

This parameter automatically changes both
[CW/CCW Vel Lim] to the same value. (for
convenience during commissioning).

Parameter Numbers

120, 121, 122, 123

Parameter Group

Velocity Cmd Data

Display Units

rpm

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

0.0 rpm

Maximum Value

8000.0 rpm

Default Value

This is determined by the motor catalog number.

[Vel LowPas BW]

Specifies the single pole low pass velocity
feedback filter bandwidth. A value of 0 disables
the filter.

Parameter Numbers

140, 141, 142, 143

Parameter Group

Vel Loop Tune

Display Units

Hz

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

0 Hz

Maximum Value

1500 Hz

Default Value

0 Hz

Advertising