Defining analog velocity – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 131

Advertising
background image

Publication 1394-5.0 — May 2000

Commissioning Your 1394 Analog Servo System

7-7

4.

Defining Analog Velocity

This procedure assumes that you have wired your 1394 Analog Servo
System and have completed the procedures in the following sections
of this chapter:

Removing and Re-Applying Power

Setting Up at the System Level

Setting Up Analog Test Points

Defining Your Motors

These procedures continue from step 4 of Defining a Reference
Source for Your Axes
.

To define analog velocity:

1. When the Ax:Mode Sel Anlg Vel message appears, press ENTER.

A message similar to the following appears:

2. Press SEL. The cursor moves to the bottom line.

3. Press either the up or down arrow until the parameter number that

you want to use for the rpm/volt gain appears.

4. Press ENTER. The system records your choice and the cursor

moves to the top line.

5. Press ENTER. A message similar to the following appears:

6. On the system module’s input board, short the velocity reference

inputs (AxVref+ and AxVref-) to null the analog velocity offset.

7. Press ENTER. A message similar to the following appears:

8. Remove the short on the velocity reference inputs.

9. Go to Defining Limits.

If you selected:

Go to:

Anlg Vel

Defining Analog Velocity.

Ana Torq

Defining Analog Torque.

Dig Vel

Defining Digital Velocity.

Dig Torq

Defining Digital Torque.

Ax:Anlg Vel Scal

+500.0 rm/v

Short Ax:Vel In

Before Proceed

Ax:Current Limit

+8.43 amps

Advertising