Option x code, Option x status, Pos cur lim – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 154: Prop gain kp, Pwr on days, Pwr on minutes, Rem. data in/out:ax

Advertising
background image

Publication 1394-5.0 — May 2000

8-18

Configuring Your 1394 Analog Servo System

[Option x Code]

Used for software options
Option 0 = Antibacklash
Option 1 = Future
Option 2 = Future
Option 3 = Future

Parameter Numbers

30, 32, 34, 36

Parameter Group

Linear List

Display Units

None

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

0

Maximum Value

65535

Default Value

0

[Option x Status]

Present status of a software option (enabled/
disabled). Once enabled via the [Option x Code]
the status will be stored in non-volatile memory
for future use.

Parameter Numbers

31, 33, 35, 37

Parameter Group

Linear List

Display Units

None

Parameter Type

Read Only

Linkable

No

Selections

0

"Disabled"

1

"Enabled"

[Pos Cur Lim]

Specifies the maximum allowable positive motor
current that can be commanded.
Important: Setting this parameter to a value
other than default will limit motor output torque
in CW direction. Automatically changed when
[Current Limit] (parameter 116) is changed.
For Example: If the value equals 100%, the Axis
Module will not deliver more than 100% to motor,
thus peak torque is limited to 100%.

Parameter Numbers

184, 185, 186, 187

Parameter Group

Torq Data

Display Units

amps

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

10% rated motor current

Maximum Value

300% rated motor current or 2 times drive rating
(whichever is less)

Default Value

300% rated motor current

[Prop Gain Kp]

This parameter controls the proportional error
gain of the velocity regulator. For example, if
KP = 1, then velocity error of 1000 rpm will
produce a (rated motor) current torque
reference.
Increase this value to attain a stiffer, more
precise response.

Parameter Numbers

368, 369, 370, 371

Parameter Group

Vel Loop Tune, AnBklsh Conf

Display Units

None

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

0

Maximum Value

1024

Default Value

0

[Pwr On Days]

Displays the number of days that the drive has
had control power applied.

Parameter Numbers

91

Parameter Group

Linear List

Display Units

None

Parameter Type

Read Only

Linkable

No

[Pwr On Minutes]

Displays the number of minutes that the drive has
presently had control power applied.

Parameter Numbers

90

Parameter Group

Linear List

Display Units

None

Parameter Type

Read Only

Linkable

No

[Rem. Data In/Out:Ax]

This series of parameters represent linkable
inputs and outputs to the SCANport Type 4/5/6/
7 DataLink inputs and outputs.

Parameter Numbers

70-85

Parameter Group

Linear List

Display Units

None

Parameter Type

Read Only

Linkable

In=No, Out=Yes