Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 109

Advertising
background image

Publication 1394-5.0 — May 2000

Wiring 1394 GMC and GMC Turbo Systems

4-29

Connecting the Position Feedback Encoder to the Feedback Input

The figure below shows the pinouts and interconnect information for
the auxiliary encoder input to the 1394-GMC.

Figure 4.32
1394-GE15 Cable Connections

1

Customer supplied 5V DC power source is required for encoder board whether encoder supply voltage is

5V or not.

To connect the encoder feedback cable to the 1394 system module:

1. Plug the 1394-GE15 cable for each DIM Axis into the correct

auxiliary encoder input on the 1394 system module as shown in
the table below. Refer to Figures 4.22, 4.23, and 4.24 for encoder
input locations.

Note:

The other end of the 1394-GE15 cable provides flying
leads and must be connected to correct signals on a
quadrature encoder.

7

1

2

3

4

5

6

8

9

12

10

11

Black

Yellow

White

Black

Green

Black

Blue

Black

Red

Black

Shield

NC

Strobe

A High

A Low

B High

B Low

Z High

Z Low

+5V Out

Common Out

1394 Encoder

Feedback Connector

Flying Leads to

Incremental Encoder or

Customer-Supplied Termination

NC

Shield

Red

Black

+5V Input

Common In

Encoder Power

(ENC. PWR)

Cable is Belden 9505

Cable is Belden 9501

1

When this axis is used:

Install the Position Feedback Input plug for:

DIM axis A into: DIM axis B into: DIM axis C into: DIM axis D into:

0 (no axis installed)

J3

J4

J5

J10

1 (axis 0 installed)

J4

J5

J10

N/A

2 (axis 0, 1 installed)

J5

J10

N/A

N/A

3 (axis 0, 1, 2 installed) J10

N/A

N/A

N/A

Advertising