Publication 1394-5.0 — May 2000

Wiring System, Axis, and Shunt Modules, and Motors (for all systems)

3-7

Ungrounded Power Configuration

As shown in the figure below, the ungrounded power configuration
does not allow for a neutral ground point. If you determine that you
have ungrounded power distribution in your plant, you need to move
the factory-installed jumper to the ungrounded power distribution
position to prevent electrostatic buildup inside the 1394. Refer to the
ground jumper procedures for the system module you need to
configure.

Figure 3.3
Ungrounded Power Configuration

!

ATTENTION: Ungrounded systems do not reference
each phase potential to a power distribution ground.
This can result in an unknown potential to earth ground.

Status

U

V

W

Conduit/4-Wire Cable

Ground grid or

Power distribution ground

PE

PE1

PE3 (drain/shield)

PE2 (wire 8)

W1 (wire 3)

V1 (wire 2)

U1 (wire 1)

1326 motor
power cable

DANGER

RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY

EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.