Auto tuning – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 272

Advertising
background image

Publication 1394-5.0 — May 2000

C-10

Using the Human Interface Module (HIM)

6. Press ENTER. The system records your choice and a message

similar to the following appears:

7. If you have more than one copy of the contents of a drive stored

in the HIM, press either the up or down arrow key until the
number assigned to the information you want appears.

8. Press ENTER. A message similar to the following appears:

Note: The numbers on the bottom of the display represent the

firmware revision of the copy stored on the HIM (left) and
the firmware revision of the system to which you will copy
the information (right).

9. Press ENTER. A message similar to the following appears:

Note: The numbers of the parameters scroll as they are copied and

more solid boxes appear on the bottom to show the status
of the copy.

10. When the copy is complete, a message similar to the following

appears:

11. Press ESC. A message similar to the following appears:

12. Press ENTER. The system records your choice and the following

message appears:

13. Press ENTER. The system saves the values that you entered and

the following message appears:

Auto Tuning

You will normally auto tune your system as part of the set up
procedure. The procedures in this section describe how to auto tune at
other times. It also includes details on parameters that are set as a
result of auto tuning.

1. Access the "ATune Config" group of parameters.

HIM -> Drive
1 FIRST

B1394 Servo Drv
3.00 --> 3.00

Drive -> HIM ##

Drive --> HIM ###
Completed

Choose Mode
EEPROM

EEPROM
Save Values

Choose Mode
EEPROM

Advertising
This manual is related to the following products: