1394 analog servo systems (1394x-sjtxx-a), Figure b.16 non-isolated series e-stop – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 253

Advertising
background image

Publication 1394-5.0 — May 2000

Interconnect and CE Diagrams

B-21

1394 Analog Servo Systems (1394

x-SJTxx-A)

The example below shows 1394 (Series C) axis modules with internal
brake and thermal switch filtering. Separate isolation power supply
and relay are not required.

Figure B.16
Non-Isolated Series E-Stop

Axis 0

Axis 1

Axis 2

Axis 3

Motor Thermal

Switch

1394 Analog Servo Input Wiring Board

1394

x-SJTxx-A

TB2

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20

TB1

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20

Contactor

Enable

Relay

24V AC/DC

or

120V AC,

50/60 HZ

STOP

START

CR1

CR1

CR1

M1

TB1

Motor brake
filter (Series C)

Motor thermal

switch filter

(Series C)

TB2

1394C-AM

xx

4 3 2 1

4 3

4 3

2 1

TB1

Motor brake
filter (Series C)

Motor thermal

switch filter

(Series C)

TB2

1394C-AM

xx

4 3 2 1

4 3

4 3

2 1

TB1

Motor brake
filter (Series C)

Motor thermal

switch filter

(Series C)

TB2

1394C-AM

xx

4 3 2 1

4 3

4 3

2 1

TB1

Motor brake
filter (Series C)

Motor thermal

switch filter

(Series C)

TB2

1394C-AM

xx

4 3 2 1

4 3

4 3

2 1

Advertising
This manual is related to the following products: