Publication 1394-5.0 — May 2000

8-6

Configuring Your 1394 Analog Servo System

[Axis Type]

Catalog number of Axis Module.

Selection codes for 1394C-AM50-IH and
1394C-AM75-IH are the same as 1394

x-AM50

and 1394

x-AM75 respectively.

Parameter Numbers

328, 329, 330, 331

Parameter Group

Configuration

Parameter Type

Read Only

Linkable

No

Selections

0

"NOT PRESENT"

2

"1394

x-AM03"

3

"1394

x-AM04"

4

"1394

x-AM07"

5

"1394

x-AM50"

6

"1394

x-AM75"

8

"1394-DIM"

[Bridge Lim]

Axis module/motor combination absolute
maximum current limit magnitude. Twice module
current rating or three times motor current rating,
whichever is less.

Parameter Numbers

260, 261, 262, 263

Parameter Group

Linear List

Display Units

amps

Parameter Type

Read Only

Linkable

No

[Bus Voltage]

Displays the present value of the DC link
(DC bus) voltage

Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems only.

Note: To determine the series of your module,

refer to Figure P.1 in the

Preface.

Parameter Numbers

39

Parameter Group

Smart Sys Data

Display Units

vlts

Parameter Type

Read Only

Linkable

No

[CCW OvSpd Vel]

Counterclockwise trip velocity for an overspeed
fault. This value is automatically set to 1000 rpm
greater then [CCW Vel Lim] if this value would be
greater then present setting.

Parameter Numbers

156, 157, 158, 159

Parameter Group

Vel Cmd Data

Display Units

rpm

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

0.0 rpm

Maximum Value

8000.0 rpm

Default Value

This is determined by the motor catalog number.

[CCW Vel Lim]

Velocity mode counterclockwise maximum
command limit. This value is automatically set to
the motor rated velocity when the motor
parameter is changed.

Parameter Numbers

132, 133, 134, 135

Parameter Group

Vel Cmd Data

Display Units

rpm

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

0.0 rpm

Maximum Value

8000.0 rpm

Default Value

This is determined by the motor catalog number.