Wiring System, Axis, and Shunt Modules, and Motors (for all systems)

5. Insert the other wire from the 230V AC power supply into

terminal 4.

6. Insert the jumper wire that came with your shunt module into

terminals 2 and 3. Refer to Figure 3.21 for the jumper’s location.

7. Tighten all screw terminals.

8. Gently pull on each wire to make sure it does not come out of its

terminal. Re-insert and tighten any loose wires.

Figure 3.21
Wire Locations for the Shunt Module Fan

1

2

3

4

Wiring the fan for 115V

1

2

3

4

Wiring the fan for 230V

To power supply

To power supply

To power supply

To power supply