Dedicated discrete i/o specifications, Serial i/o specifications – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 210

Advertising
background image

Publication 1394-5.0 — May 2000

A-12

Specifications

Dedicated Discrete I/O Specifications

The table below lists the dedicated discrete I/O specifications for the
system module (1394x-SJTxx-C-xx, -L-xx, and -T-xx systems).

Serial I/O Specifications

The table below lists the dedicated serial I/O specifications for the
system module (1394x-SJTxx-C-xx, -L-xx, and -T-xx systems).

The:

Is:

Number of dedicated discrete
inputs

16 (4 each for axis 0, 1, 2, and 3)

Dedicated discrete input
functions

Home limit switch, positive overtravel limit switch, negative
overtravel limit switch, position registration, and thermal
fault.

Input type

Optically isolated

Operating voltage

24V DC, 28V DC maximum or 5V DC nominal; 10V DC
maximum for position registration inputs

Input On current

12 mA per input (nominal); 2.5 mA for position registration
inputs

Input impedance

2 kohms (resistive) per input; 8.8 kohms (resistive) for 24
V position registration inputs.

Input response time

5 ms maximum; 1

µ

s maximum for position registration

inputs

The:

Is:

Number of serial channels

2 (serial port A and serial port B)

Channel type

Optically isolated RS-232 or RS-422; each channel
individually configured via internal switch

Information code

ASCII

Baud rate

User-selectable up to 128 kbaud (rs-422); 115.2 kbaud
(RS-232)

Number of start bits

One

Number of stop bits

One

Word length

8 bits (7 data bits plus 1 parity bit)

Parity

Space parity transmitted; receive parity ignored (may be
mark, space, even, or odd)

Duplex

Full or half (user-selectable)

Data synchronization

XON (control-q)/XOFF (control-s)

Front panel connectors

IBM-PC/AT compatible 9-pin D-type female

RS-422 termination

User-selectable 220 ohm resistor via internal switch