HP R4.2 User Manual

Page 463

Advertising
background image

A

Summary of Commands

detach

UCS 1000 R4.2 Administration 585-313-507

Issue 3 April 2000 424

-n

— This optional parameter disables prompting from the system

whether to wait until a conflict has been resolved (see the

-i

option below)

or to terminate the request to detach.

-i

— This optional parameter is used to enable secondary command

registration. If T1 diagnostics are being run, this option allows the
“detaching” of another card. If

-i

is used and another maintenance

command is being run (

remove

,

detach

,

attach

,

restore

,

diagnose), the

request to detach

is blocked and a message is printed to the screen. If

-i

is not used and any maintenance command is being run, the request to
detach is blocked and a message is printed to the screen.

If the command is permitted to run, a check is made to see if the
command is in conflict with another. A command is in conflict if the card or
card associated with it:

~

Is the T1 card being diagnosed

~

Will cause a change in the existing TDM bus master assignment

~

Has an interdependency with the T1 card being diagnosed (for
example, PRI)

If one of the above conflicts exist and

-n

is not used, the user is asked

whether to wait until the conflict is resolved or to terminate the request. If
T1 diagnostics are executing online tests and a conflict is detected, the
detach

command is blocked. If T1 diagnostics are executing offline tests

and a conflict is detected, the user is asked whether to wait until the
conflict is resolved or to terminate the request to detach.