Remote Gateway 9150 Installation and Administration Guide

Installing the Remote Gateway 9150 unit

Standard 3.1

2

Place the screws in a safe place where they cannot be lost.

3

Ensure the Remote Gateway 9150 unit is placed top side up.

4

Remove the cover as follows:

a. Grasp both sides of the Remote Gateway 9150 unit.

b. Slide the cover toward you.

c. Lift the cover off the unit.

d. Put the cover aside.

5

Turn the Remote Gateway 9150 unit so the rear panel faces you.

Note: This allows you to read the labels on the Remote Gateway 9150 unit
circuit board.

6

Perform module installation as required.

Note: For instructions, refer to “To install trunk interface or DSP application
modules:” on page 96.

7

Replace the cover as follows:

!

Carefully slide the top cover into position over the circuit board so that
the holes along the top edge of the rear panel are aligned.

!

Replace the four screws on the top.

!

Replace the two screws on the sides.

!

Turn the Remote Gateway 9150 unit over and replace the eight screws
on the bottom.

8

Continue with “Installing the Remote Gateway 9150 unit” on page 98.