Automatic teis (terminal endpoint identifiers), Entering the bri settings, Online mode – Nortel Networks 9150 User Manual
Page 257

Remote Gateway 9150 Installation and Administration Guide
227
January 2005
Configuring the Remote Gateway 9150 unit
Automatic TEIs (Terminal Endpoint Identifiers)
BRI modules must be used in a point-to-point configuration if using automatic
TEI assignments. They cannot be used in a multi-point configuration. Also,
make sure that no other ISDN devices are on the line.
Entering the BRI settings
To enter the BRI settings:
1
Complete the fields as described in “BRI Configuration field descriptions”
on page 228.
2
Click on the OK button
Result: Configuration Manager writes the changes to a temporary file on
the administration PC.
3
Click on the Send button to update the Remote Gateway 9150 unit with the
new information.
Note: To save changes to the Remote Gateway 9150 unit’s Flash memory,
select Upload
→
Save to Flash from the Menu Bar.
United Kingdom
A-law
Australia
A-law
DPNSS 1
µ-law
DASS 2
µ-law
Line Type
Default Coding Law