Remote Gateway 9150 Installation and Administration Guide

341

January 2005 Administration

3

Enter the IP address of the TFTP server into the IP Address fields.

Note: Since the TFTP server application runs on your administration PC,
this is the IP address of the PC.

4

Click on the Browse button.

Result: The Open dialog box displays, similar to the following:

5

Ensure the Files of type drop down box shows Upgrade Files(*.UPG).

6

Navigate to the folder where the firmware file is located.

7

Select the file, and then click on the Open button.

Examples:

!

For motherboard firmware, select 9150-100.upg, and then click on the
Open button.

!

For ISDN BRI module firmware, select briv15u.upg, and then click on
the Open button.

Result: The Software Upload dialog box re-displays. The file you selected
is shown in the Uploaded File field.

8

Click on the Upload button.

Wait until the file uploads completely before entering any other commands.
The Log Report field displays a confirmation message when the upgrade is
complete.

9

Restart the Remote Gateway 9150 unit.