Configuring the Remote Gateway 9150 unit

You must configure Bridge Port parameters on both the host PBX and the
Remote Gateway 9150 unit. For every Bridge Port defined on the Remote
Gateway 9150 unit you must configure an SCR key with voice capability on key
0 for that port on the host PBX. For more information on configuring SCR keys
on a host PBX refer to your PBX documentation.

Note: Local Only digital telephone sets do not support conference calls to a
local Remote Gateway 9150 unit or to a host PBX. Local Only digital telephone
sets can dial host PBX DNs using an enabled Bridge Port.

Configuring Bridge Ports reduces the total number of ports available from the
RLC.

Call processing capabilities and station settings

Each station can be defined as a telephone that can process:

!

local calls only

!

remote calls only

!

local and remote calls

Stations defined with local call capability are further defined with telephone
features and local call appearance keys. Stations that are defined with remote
call capability do not need to be further configured because they inherit their
features and call appearance keys from their associated port configurations on
the host PBX.

Local call capability
Stations defined as local can place and receive calls through the local PSTN or
to other stations at the Remote Gateway 9150 site. Calls through the host PBX
are not allowed.

Local stations are not associated with RLC ports.

Remote call capability
Stations defined as remote are associated with RLC ports, and can place and
receive calls through the host PBX only. Calls through the local PSTN are not
allowed.