Nortel Networks 9150 User Manual

Page 507

Advertising
background image

Remote Gateway 9150 Installation and Administration Guide

477

January 2005 Display

log

definitions

Statistic

Definition

LOG NUMBER

91

DESCRIPTION

This log indicates the status of a BRI module that has started (or
restarted) because of a system startup or manual restart.

SEVERITY

WARNING

TASK

BRI manager

PRODUCT

9150

CANCELLATION

None

ACTION TO BE TAKEN

Monitor the BRI module. If the cause is not a user-initiated reset, a
problem exists with either the BRI hardware or software. Try
replacing the BRI module, or swapping the BRI module with another
slot that shows no problem. If the problem persists, contact Nortel.
Note: MMI code (via MMI_SW_UPLD_LOG_ID) reports the status of
a BRI module restart resulting from an upload command.

PARAMETERS

1) BRI Module
2) Reset status (SUCCESS or FAILURE), activity leading to the error

(System Startup, User Reset)

DISPLAYED TEXT

BRI #P1 boot status: P2